A Basic Question About Load Balancing and Power Factor Correction in Three-phase Systems

What is the main reason for balancing the loads in a three-phase system. Maybe for a three-phase induction motor the reason is more clear. But imagine a house power entry with three line voltages as phase A, phase B and phase C; one neutral and one earth into the building. As far as I know the loads on all phases must be somehow balanced.Answers to your more recent question tell you that statistically, loads are expected to be balanced due to the number of simultaneous consumers but, there are no guarantees that all three phases will have equal magnitude currents and, some current will inevitably flow down the neutral connection.Does that also mean their power factors should also be close?It would be nice for the generating companies if the individual PFs and currents were balanced but this won't happen and there will be differences that the generating system has to cope with.What is the real reason behind all these balancing?To avoid too much current being taken down one single phase wire is a significant reason. This can unduly affect the voltage seen on some phases with respect to neutral and there are rules to follow that limit how far out this voltage supply can be. If one phase is drawing a lot of current with respect to the others, its local load voltage might be driven down too much. Conversely, there are situations when this happens that the phase voltages of under-utilized lines will increase.I also hear about PF compensation with capacitors. What is the main reason to make the power factor close to 1?PF correction sets out to reduce the current taken down power lines. Consider this picture: -The green line is important because it is the real power you get billed on but, many appliances also use reactive power that adds to the current taken by appliance. That reactive power is the vertical blue line. Together, reactive and real power produce the apparent power i.e. the VA (volt amps) you could measure with a voltmeter and ammeter.Note that the apparent power can never be smaller than the real power and this means that the current supplied by the generating station is higher than what is needed to produce X kilowatts for the consumer.So, PF correction sets out to add capacitors across the load in an attempt to reduce reactive power to close to zero. This makes PF 1.Most traditional power loads are motors and they have an inductive current that is in the direction of the "pointing-up" blue line. If you add capacitors these naturally have a pointing-down blue line hence the two effects cancel out.It's exactly the same when you have a parallel tuned circuit - the impedance becomes high at resonance therefore the current drops leaving just the current needed to supply the "kilowatts".This sort of PF correction is for the benefit of the power companies in that the net current they have to feed down lines is smaller. This means that thinner cables are needed.

I know basically about phasor representation of line voltages and active reactive power concepts in three-phase systems.

But what I'm wondering is the reasons of two things I hear a lot.

1-) What is the main reason for balancing the loads in a three-phase system. Maybe for a three-phase induction motor the reason is more clear. But imagine a house power entry with three line voltages as phase A, phase B and phase C; one neutral and one earth into the building. As far as I know the loads on all phases must be somehow balanced.

Does that mean they should carry same amount of currents? Does that also mean their power factors should also be close? What is the real reason behind all these balancing?

2-) I also hear about PF compensation with capacitors. What is the main reason to make the power factor close to 1? Why is the power factor adjusted?

hot searches
KAMA 173F 디젤 엔진 농업 기계 Chongqing Motor Hoes를 가진 AW-N3C 5.5HP 9HP 디젤 Motorzada 경운기 / Intercultivator / Power Tiller with Lightings 20HP 30HP 40HP 50HP Mini Tractor Factory Good Price Tractor China Top Sale Small Tractor Four Wheels Tractor 농업을 위한 가솔린 힘 경운기 기계 7HP 6.5HP Motoculteur 농업 2WD 핸드 푸시 미니 워킹 트랙터 Most popular products agricultural pesticide water garden sprayer machine1 China Competitive Price Two Wheel Walking Tractor Two Wheels Walking Behind Tractors Hot Sale 50KW cheap Diesel heater with outdoor use1 가득 차있는 장치 드라이브 2019 원심 경운기 경운기 경운기/경운기 기계 Orchards rotavator를위한 신기술 POWERTEC 1000w electric portable hand lawn mower
뜨거운 기사
What Led to Racial Relations Being Better in Namibia and Botswana, Compared to South Africa?
232
Is there anyone recovered from covid-19? Can you share your hospital bills?
190
Which would win, a Landkreuser P 1000 Ratte and Maus tank or a Bob Semple tank?
174
UNICAR Guatemala, the Aortic Valve Replacement Hospital in Guatemala City
165
A poultry farmer collects eggs every morning. There are 50 broken eggs per collection on average. What is the probability that more than 60 eggs might be
150
Chinese Government Assists Dominica with 2,500 Solar Street Light with Battery and Panel
140
Is There a Reason That I Need a HUD App'd Water Heater Or a Special Water Heater for a Mobile Home/t
132
Rite Academy Hyderabad Best Institute for NDT
131
Why did you learn Machine Learning?
131
Farm Machinery in Ethiopia Bolstering the Agricultural Backbone
130
Motor related articles
Tips to Help You Design the Perfect Solar Battery for That Party
Functional Features and Application Introduction of TG452 Series Intelligent Street Lamp Gateway
What Is the Best the Best Solar Street Light for You? - the Best Solar Street Light Reviews
IGBT of Fuji Motor Electronic Equipment Technology
Is a Metal Roof Right for You | Billy
너는 좋아 할거야
제품 도매 제품 농업 기계
KAMA 173F 디젤 엔진 농업 기계 Chongqing Motor Hoes를 가진 AW-N3C
5.5HP 9HP 디젤 Motorzada 경운기 / Intercultivator / Power Tiller with Lightings

Copyright © 2020  Shandong Abusair Agricultural Machinery Co,. Ltd- |  Sitemap

Multifunctional farm Abusair machinery  |  Tea Professional Cultivator farm machinery